To see a power-flow example of a larger system, open PowerWorld Simulator case in this Example(see Figure 1).

power world simulator power system analysis problems

Use PowerWorld Simulator to confirm this result also determine the magnitude and time of the largest bus frequency deviation.ĮXAMPLE 1 Power-flow program: 37-bus system Analytically determine the steady-state frequency error in Hz following this contingency.

#Power world simulator power system analysis problems generator

The contingency is the loss of the generator at bus 50, which initially has 42.1 MW of generation. Each generator is modeled using a two-axis machine model, an IEEE Type 1 exciter and a TGOV1 governor with R = 0.05 per unit (a summary of the generator models is available by selecting either Stability Case Info, Transient Stability Generator Summary which includes the generator MVA base, or Stability Case Info, Transient Stability Case Summary). Open PowerWorld Simulator case in this Problem, which includes a transient stability representation of the system from Example 1. Design Project 1 discusses these options.FIGURE 1Screen for Example 1 showing the initial flows … Get solutions Get solutions Get solutions done loading Looking for the textbook? Control actions and/or design improvements are needed to correct these problems. Since there are now several bus and line violations, the power system is no longer at a secure operating point.

power world simulator power system analysis problems

The lowest per-unit voltage is now 0.9104 at AMANDA69 and the highest percentage line loading is 134.8%, on the line from HOMER69 to LAUF69. Once the line is removed, use single solution to resolve the power flow. An alternative approach is to find the line on the one-line (it is in the upper-lefthand portion) and then click on one of its circuit breakers. One approach is to locate the line on the Line and Transformer Records display and then double-click on the Status field to change its value. Initially the highest percentage loading is 64.9% on the line from UIUC69 to BLT69 circuit 1.There are several ways to remove the TIM69 to HANNAH69 line. Left-click on % of Max Limit to sort the lines by percentage loading. Next, select Case Information, Network, Lines and Transformers… to view the Line and Transformer Records display. The lowest initial voltage magnitude is 0.9902 at bus DEMAR69. To quickly determine the lowest per-unit voltage magnitude, left-click on the PU Volt column header to sort the column (clicking a second time reverses the sort). Use Tools, Play to animate the one-line and Tools, Pause to stop the animation.Determine the lowest per-unit voltage and the maximum line/transformer loading both for the initial case and for the case with the line from bus TIM69 to HANNAH69 out of service.SOLUTIONUse single solution to initially solve the power flow, and then Case Information, Network, Buses… to view a listing of all the buses in the case. The one-line can be panned by pressing the arrow keys, and it can be zoomed by pressing the hctrli with the up arrow key to zoom in or with the down arrow key to zoom out. This case models a 37-bus, 9-generator power system containing three different voltage levels (345 kV, 138 kV, and 69 kV) with 57 transmission lines or transformers. Use PowerWorld Simulator to confirm this result also determine the magnitude and time of the largest bus frequency deviation.EXAMPLE 1 Power-flow program: 37-bus systemTo see a power-flow example of a larger system, open PowerWorld Simulator case in this Example(see Figure 1). This problem has been solved: Solutions for Chapter 12 Problem 11P: Open PowerWorld Simulator case in this Problem, which includes a transient stability representation of the system from Example 1.